GE 165 PSX PMSX EAS

GE 165 PSX PMSX EAS
  • PERKINS water cooled diesel engine - 1500 rpm
  • Common-rail engine with electronic governor
  • EP6 engine protection
  • GE 145 PS/PSX – STAMFORD three-phase synchronous alternator
  • GE 145 PMS/PMSX – MARELLI three-phase synchronous alternator
  • Four pole circuit breaker
  • Oil drain pump
  • Bunded base
  • Ready for connection to automatic transfer unit
  • Meets EC directives for safety and noise level

 

Standard equipment

  • Diesel engine
  • Water Cooling
  • Battery 12V
  • Fuel level gauge
  • Engine protection
  • Electric starter
  • Low press. shut down
  • High water shut down
  • Over speed shut down
  • Low fuel shut down
  • Battery charge alarm
  • Rpm meter
  • Hours meter
  • Battery voltmeter
  • Voltmeter
  • Frequency meter
  • Remote start
  • Synchronous alternator
  • Automatic Voltage Regulator
  • Circuit breaker
  • Terminal block
  • Ammeter
  • Voltmeter phase selector
  • Emergency stop button
  • Siren
  • Ready for EAS/TCM
  • Central lifting eye
  • Cold start aid

 

Factory installation options

  • Electrical panel with sockets :1x400V 125A 3P+N+T CEE - 1x400V 63A 3P+N+T CEE - 1x400V 32A 3P+N+T CEE - 1x400V 16A 3P+N+T CEE - 2 x 230V 16A 2P+T CEE. The electrical panel requires an electrical protection : ELR-Earth Leakage Relay (GFI) or Isometer (Insulation monitors)
  • 50/60 Hz Selector
  • Earth Leakage Relay
  • Isometer (Insulation monitors)
  • Radio-control
  • Permanent Magnet Generator
  • Volt and Hz adjustable from control panel
  • Gauges – water temperature and oil pressure
  • Water heater WH
  • Automatic fuel transfer pump (delivered loose)
  • Fuel tank 120l
  • Fuel tank 350l
  • 3-way valve fuel system with quick connection for external fuel tank supply

 

Options on request

  • 400 plugs
  • 230 plugs
  • Automatic transfer unit (AMF) EAS 170-805
  • Remote control TCM35
  • Earthing kit

 

Version in request

  • 24 h autonomy version

 

Technical data

A.C. GENERATION - 50 Hz: Three-phase syncronous alternator, self-excited, self- regulated, brushless

*Stand-by three-phase power: 165 kVA (132 kW) / 400 V / 238.1 A

*P.R.P. three-phase power: 150 kVA (120 kW) / 400 V / 216.5 A

*P.R.P. single-phase power: 55 kVA / 230 V / 239.1 A

Cos φ: 0.8

Insulation class: H

*Output powers according to ISO 8528-1

ENGINE: 4-stroke diesel, common rail, turbocharged-air to air charge cooled , direct injection, water cooled

Model: PERKINS 1106C-E66TAG3

*Stand-By net power: 143.9 kW (195.7 HP)

*P.R.P. net power: 129.5 kW (176.1 HP)

Cylinders/ Displacement: 6/ 6.6 l (6600 cm3)

Speed: 1500 rpm

Fuel consumption (75% of P.R.P.): 25.8 l/h

*Powers according to ISO 3046-1

GENERAL SPECIFICATIONS

Tank capacity: 230 l

Running time (75% of P.R.P.): 9 h         

IP protection degree: IP 44

*Dimensions LxWxH (mm): 3000x1200x1800 (GE 165 PS/PMS EAS)

                                          3400x1200x1800 (GE 165 PSX/PMSX EAS)

*Dry weight: 2160 kg (GE 165 PS/PMS EAS)

                     2230 kg (GE 165 PSX/PMSX EAS)

**Measured acoustic power LwA (pressure LpA):

   96 dB(A) (71 dB(A) @ 7 m) (GE 165  PS/PMS EAS)

   93 dB(A) (68 dB(A) @ 7 m) (GE 165 PSX/PMSX EAS)

**Guaranteed acoustic power LwA (pressure LpA):

   97 dB(A) (72 dB(A) @ 7 m) (GE 165 PS/PMS EAS)

   94 dB(A) (69 dB(A) @ 7 m) (GE 165 PSX/PMSX EAS)

*Dimensions and weight without trolley/trailer. **Acoustic power according to European Directive 2000/14/EC