GE 12000 SXC/GS EAS

GE 12000 SXC/GS EAS
  • ES engine protection
  • Single-phase synchronous alternator
  • Output sockets 230V: 1 x 230V 63A 2P+T CEE

                                        1 x 230V 32A 2P+T CEE - 1 x 230V 16A 2P+T CEE

  • Output sockets 230V/115V: 1 x 230V 32A 2P+T

                                                 1 x 230V 16A 2P+T

                                                 2 x 115V 32A 2P+T - 2 x 115V 16A 2P+T

  • ELCB-GFI (Ground Fault Interruptor)
  • Circuit breaker
  • Super silenced
  • Trailer (option)
  • Ready for connection to automatic transfer unit (only 230V Version)
  • Meets EC directives for safety and noise level

 

Standard equipment

  • Diesel engine
  • Air Cooling
  • Electric starter
  • Battery 12V
  • Engine protection
  • Oil pressure shut down
  • High temp. engine shut down
  • Low fuel indicator
  • Hour meter
  • Central lifting eye
  • Synchronous alternator
  • Sockets 1~
  • ELCB-GFI
  • Circuit breaker
  • Thermal shut off
  • Voltmeter frequency meter
  • Ready for EAS/TCM
  • Local/remote start selector

 

Options on request

  • 230V plugs
  • 115V plugs
  • Remote control (EAS Version)
  • Automatic transfer unit (AMF) EAS 17M-805
  • Tank locking cap
  • Trolley CTM300
  • Site tow CTL300
  • Road trolley CTV4

 

Factory installation option

  • Oil heater OH

 

Technical data

A.C. GENERATION - 50 Hz: Single-phase synchronous alternator,self-excited, self-regulated, brushless

*Stand-by single-phase power: 13.5 kVA (12.1 kW) / 230 V / 58.7 A

*P.R.P. single-phase power: 12 kVA (10.8 kW) / 230 V / 52.5 A

*Stand-by single-phase power (115V): 13.5 kVA (12.1 kW) / 115 V / 117.4 A

*P.R.P. single-phase power (115V): 12 kVA (10.8 kW) / 115 V / 104.3 A

Cos φ : 0.9

Insulation class: H

*Output powers according to ISO 8528-1

ENGINE: 4-stroke diesel, air cooled, direct injection

Model: Lombardini 12LD 477/2

*Stand-By net power: 14.9 kW (20.3 HP)

*P.R.P. net power: 13.5 kW (18.4 HP)

Cylinders/ Displacement: 2/ 954 cm3

Speed: 3000 rpm

Fuel consumption (75% of P.R.P.): 2.8 l/h

*Powers according to ISO 3046-1

GENERAL SPECIFICATIONS

Tank capacity: 23 l

Running time (75% of P.R.P.) : 8.2 h       

IP protection degree: IP 23

*Dimensions LxWxH (mm): 1320x790x750 mm

*Dry weight: 297 kg

**Measured acoustic power LwA (pressure LpA): 96 dB(A) (71 dB(A) @ 7m)

**Guaranteed acoustic power LwA (pressure LpA): 96 dB(A) (71 dB(A) @ 7m)

* Dimensions and weight without trolley/trailer. **Acoustic power according to European Directive 2000/14/EC