GE 12000 LD/GS

GE 12000 LD/GS
  • Lombardini air cooled diesel engine - 3000 rpm
  • Electric starter
  • Three phase synchronous alternator
  • Output sockets: 1 x 400V 32A 3P+N+T CEE

                             1 x 230V 32A 2P+T CEE - 1 x 230V 16A 2P+T SCHUKO

  • ELCB-GFI (Ground Fault Interruptor)
  • Circuit breaker
  • Wrap around protective frame
  • Trolley (option)
  • Meets EC directives

 

Standard equipment

  • Diesel engine
  • Air Cooling
  • Electric starter
  • Battery 12V
  • Oil pressure indicator
  • Battery Charge indicator
  • Hours-meter
  • Synchronous alternator
  • Sockets 3~
  • Sockets 1~
  • ELCB-GFI
  • Circuit breaker
  • Thermal shut off
  • Voltmeter

 

Options on request

  • 400V plug
  • 230V plug
  • Earthing kit
  • Manual trolley CTM10

 

Technical data

A.C. GENERATION - 50 Hz : Three-phase synchronous alternator,self-excited, self-regulated

*Stand-by three-phase power : 12 kVA (9.6 kW) / 400 V / 17.3 A

*P.R.P. three-phase power : 11 kVA (8.8 kW) / 400 V / 15.9 A

*P.R.P. three-phase power : 6 kVA / 230 V / 26 A

Cos φ : 0.8

Insulation class: H

*Output powers according to ISO 8528-1

ENGINE : 4-stroke diesel, air cooled, direct injection

Model : Lombardini 25LD 425/2

*Stand-By net power : 11.5 kW (15.6 HP)

*P.R.P. net power : 10.5 kW (14.3 HP)

Cylinders/ Displacement : 2/ 851 cm3

Speed : 3000 rpm

Fuel consumption (75% of P.R.P.) : 2.2 l/h

*Powers according to ISO 3046-1

GENERAL SPECIFICATIONS

Tank capacity : 18 l

Running time (75% of P.R.P.) : 8.2 h                   

IP protection degree : IP 23

*Dimensions LxWxH (mm) : 935x580x645

*Dry weight : 156 kg

**Acoustic LwA (pressure LpA) : 99 dB(A) (74 dB(A) @ 7m)

*Dimensions and weight without trolley/trailer. **For indoor use / For fixed